{"id":1128,"date":"2026-07-28T09:30:00","date_gmt":"2026-07-28T09:30:00","guid":{"rendered":"https:\/\/qixiangmaterial.com\/?p=1128"},"modified":"2026-07-28T09:30:00","modified_gmt":"2026-07-28T09:30:00","slug":"sic-heating-element-wiring-diagram","status":"publish","type":"post","link":"https:\/\/qixiangmaterial.com\/es\/sic-heating-element-wiring-diagram\/","title":{"rendered":"Diagrama de cableado del elemento calefactor de SiC: c\u00f3mo planificar conexiones en serie, paralelas y de zona"},"content":{"rendered":"<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><h2>Tabla de contenidos<\/h2><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">SiC heating element wiring diagram is not an isolated component decision. For electrical engineers, furnace builders, and commissioning teams, it connects the thermal duty of the furnace to the electrical system, mechanical layout, process atmosphere, and maintenance plan. The practical risk is that a drawing may look electrically complete while hiding unequal resistance, excessive branch current, or unsafe terminal loading. A useful engineering review therefore starts with operating evidence, not a catalog value in isolation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This guide explains how to approach SiC heating element wiring diagram as a documented engineering task. The objective is a readable connection plan that installers can verify before energizing the furnace. It does not replace the furnace designer\u2019s electrical and safety calculations, but it gives buyers and plant teams a structured way to ask better questions, compare options, and identify missing information before an order or shutdown.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why SiC heating element wiring diagram matters<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A sound SiC heating element wiring diagram decision affects temperature stability, available control range, connection temperature, and the ability to maintain the furnace without unplanned redesign. A specification should describe the real cycle, load, chamber arrangement, power supply, and atmosphere. Those details are more useful than relying on maximum ratings alone. Review the <a href=\"https:\/\/qixiangmaterial.com\/es\/products\/\">productos de calefacci\u00f3n industrial<\/a> cuando el proyecto llegue a ese punto de decisi\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Treat the current furnace condition as part of the design input. Record element positions, resistance values where relevant, controller output, transformer taps, alarm history, and visible mechanical conditions. When SiC heating element wiring diagram is supported by those records, the team can separate a component problem from a zone, connection, sensor, or operating problem.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. Record every element resistance on the drawing<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SiC heating element wiring diagram should address this point before final dimensions or wiring are released. Record every element resistance on the drawing is important because a value that is acceptable for one zone or process step may be unsuitable elsewhere in the same furnace. Write the requirement in measurable terms and identify who will verify it. The result should be a clear input, calculation, drawing note, or inspection item rather than an undocumented judgment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Review the associated failure mode as well as the preferred operating condition. If the check is omitted, the symptoms may appear later as uneven power, overheated connections, limited controller range, repeated trips, or premature element replacement. A disciplined SiC heating element wiring diagram review links the symptom to evidence and assigns a corrective action before production depends on the system. Review the <a href=\"https:\/\/qixiangmaterial.com\/es\/silicon-carbide-heating-element-dimensions-guide\/\">heating element dimensions guide<\/a> cuando el proyecto llegue a ese punto de decisi\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. Choose series or parallel grouping deliberately<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SiC heating element wiring diagram should address this point before final dimensions or wiring are released. Choose series or parallel grouping deliberately is important because a value that is acceptable for one zone or process step may be unsuitable elsewhere in the same furnace. Use a marked-up drawing so that electrical and mechanical information refer to the same position. The result should be a clear input, calculation, drawing note, or inspection item rather than an undocumented judgment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Review the associated failure mode as well as the preferred operating condition. If the check is omitted, the symptoms may appear later as uneven power, overheated connections, limited controller range, repeated trips, or premature element replacement. A disciplined SiC heating element wiring diagram review links the symptom to evidence and assigns a corrective action before production depends on the system. Review the <a href=\"https:\/\/qixiangmaterial.com\/es\/silicon-carbide-heating-element-resistance\/\">gu\u00eda de selecci\u00f3n de resistencia<\/a> cuando el proyecto llegue a ese punto de decisi\u00f3n.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" src=\"https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/DH-equal-diameter-3-1536x960.jpg.webp\" alt=\"Elementos calefactores rectos de carburo de silicio para hornos industriales\" class=\"wp-image-565\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">3. Balance resistance across parallel branches<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SiC heating element wiring diagram should address this point before final dimensions or wiring are released. Balance resistance across parallel branches is important because a value that is acceptable for one zone or process step may be unsuitable elsewhere in the same furnace. Check the proposed condition at startup, normal production, and the most demanding credible cycle. The result should be a clear input, calculation, drawing note, or inspection item rather than an undocumented judgment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Review the associated failure mode as well as the preferred operating condition. If the check is omitted, the symptoms may appear later as uneven power, overheated connections, limited controller range, repeated trips, or premature element replacement. A disciplined SiC heating element wiring diagram review links the symptom to evidence and assigns a corrective action before production depends on the system. Review the <a href=\"https:\/\/qixiangmaterial.com\/es\/sic-heating-element-terminals\/\">gu\u00eda de conexi\u00f3n de terminales<\/a> cuando el proyecto llegue a ese punto de decisi\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Show transformer taps and control devices<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SiC heating element wiring diagram should address this point before final dimensions or wiring are released. Show transformer taps and control devices is important because a value that is acceptable for one zone or process step may be unsuitable elsewhere in the same furnace. Compare calculated values with measured furnace data whenever an existing installation is available. The result should be a clear input, calculation, drawing note, or inspection item rather than an undocumented judgment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Review the associated failure mode as well as the preferred operating condition. If the check is omitted, the symptoms may appear later as uneven power, overheated connections, limited controller range, repeated trips, or premature element replacement. A disciplined SiC heating element wiring diagram review links the symptom to evidence and assigns a corrective action before production depends on the system. Review the <a href=\"https:\/\/qixiangmaterial.com\/es\/silicon-carbide-heating-element-replacement\/\">gu\u00eda de especificaciones de reemplazo<\/a> cuando el proyecto llegue a ese punto de decisi\u00f3n.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" src=\"https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/DB-type-silicon-carbide-heating-element-3-1536x960.jpg.webp\" alt=\"Elemento calefactor de carburo de silicio tipo DB\" class=\"wp-image-566\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">5. Identify terminal hardware and conductor routes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SiC heating element wiring diagram should address this point before final dimensions or wiring are released. Identify terminal hardware and conductor routes is important because a value that is acceptable for one zone or process step may be unsuitable elsewhere in the same furnace. Record assumptions explicitly so later changes in load, atmosphere, or control settings can be reviewed. The result should be a clear input, calculation, drawing note, or inspection item rather than an undocumented judgment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Review the associated failure mode as well as the preferred operating condition. If the check is omitted, the symptoms may appear later as uneven power, overheated connections, limited controller range, repeated trips, or premature element replacement. A disciplined SiC heating element wiring diagram review links the symptom to evidence and assigns a corrective action before production depends on the system. Review the <a href=\"https:\/\/qixiangmaterial.com\/es\/furnace-atmosphere-sic-heating-elements\/\">gu\u00eda de atm\u00f3sfera de horno<\/a> cuando el proyecto llegue a ese punto de decisi\u00f3n.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1900\" height=\"1188\" src=\"https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-3-2-1.jpg.webp\" alt=\"Accesorios de conexi\u00f3n de elementos calefactores\" class=\"wp-image-561\" srcset=\"https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-3-2-1.jpg 1900w, https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-3-2-1-300x188.jpg 300w, https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-3-2-1-1024x640.jpg 1024w, https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-3-2-1-768x480.jpg 768w, https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-3-2-1-1536x960.jpg 1536w, https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-3-2-1-600x375.jpg 600w\" sizes=\"(max-width: 1900px) 100vw, 1900px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">6. Add isolation, protection, and test points<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SiC heating element wiring diagram should address this point before final dimensions or wiring are released. Add isolation, protection, and test points is important because a value that is acceptable for one zone or process step may be unsuitable elsewhere in the same furnace. Keep the acceptance method simple enough for commissioning and future maintenance teams to repeat. The result should be a clear input, calculation, drawing note, or inspection item rather than an undocumented judgment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Review the associated failure mode as well as the preferred operating condition. If the check is omitted, the symptoms may appear later as uneven power, overheated connections, limited controller range, repeated trips, or premature element replacement. A disciplined SiC heating element wiring diagram review links the symptom to evidence and assigns a corrective action before production depends on the system. Review the <a href=\"https:\/\/qixiangmaterial.com\/es\/contact-us\/\">p\u00f3ngase en contacto con el equipo de ingenier\u00eda<\/a> cuando el proyecto llegue a ese punto de decisi\u00f3n.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1900\" height=\"1188\" src=\"https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-7-2-1.jpg.webp\" alt=\"Accesorios para elementos calefactores de hornos industriales\" class=\"wp-image-563\" srcset=\"https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-7-2-1.jpg 1900w, https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-7-2-1-300x188.jpg 300w, https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-7-2-1-1024x640.jpg 1024w, https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-7-2-1-768x480.jpg 768w, https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-7-2-1-1536x960.jpg 1536w, https:\/\/qixiangmaterial.com\/wp-content\/uploads\/2026\/01\/Accessories-7-2-1-600x375.jpg 600w\" sizes=\"(max-width: 1900px) 100vw, 1900px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">A comparison table for SiC heating element wiring diagram<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La siguiente tabla proporciona una forma pr\u00e1ctica de comparar tres niveles de informaci\u00f3n del proyecto. Es intencionalmente cualitativo porque los valores finales dependen del horno, el dise\u00f1o el\u00e9ctrico, el ciclo del proceso y la geometr\u00eda del elemento.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Nivel de revisi\u00f3n<\/th><th>Informaci\u00f3n disponible<\/th><th>Resultado probable<\/th><\/tr><\/thead><tbody><tr><td>Solicitud incompleta<\/td><td>S\u00f3lo el nombre de un producto o la temperatura m\u00e1xima<\/td><td>El proveedor debe asumir dimensiones y condiciones operativas cr\u00edticas<\/td><\/tr><tr><td>Solicitud t\u00e9cnica b\u00e1sica<\/td><td>Dimensiones, resistencia o potencia, cantidad y temperatura del horno<\/td><td>Un punto de partida viable que a\u00fan necesita comprobaciones de conexi\u00f3n y procesos<\/td><\/tr><tr><td>Solicitud lista para ingenier\u00eda<\/td><td>Dibujo, disposici\u00f3n de circuitos, atm\u00f3sfera, ciclo, carga, controles, inspecci\u00f3n y registros<\/td><td>Una propuesta t\u00e9cnicamente comparable con menos interfaces sin resolver<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">For most industrial projects, SiC heating element wiring diagram should reach the engineering-ready level before purchase approval. The purpose is not to create unnecessary paperwork. It is to make sure the thermal, electrical, mechanical, and operational interfaces are owned by the right people.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Flujo de trabajo de c\u00e1lculo y documentaci\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Comience con una descripci\u00f3n de una l\u00ednea del proceso y un dibujo controlado del horno. Agregue el cronograma de elementos, las conexiones de zona, el voltaje disponible, la disposici\u00f3n del controlador y los l\u00edmites operativos relevantes. Utilice el <a href=\"https:\/\/en.wikipedia.org\/wiki\/Ohm%27s_law\" target=\"_blank\" rel=\"noopener\">Referencia a la ley de Ohm<\/a> como referencia el\u00e9ctrica b\u00e1sica, aplique el m\u00e9todo de c\u00e1lculo aprobado por el dise\u00f1ador del equipo y las reglas el\u00e9ctricas locales.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A continuaci\u00f3n, registre los supuestos y compru\u00e9belos con los datos de producci\u00f3n disponibles. El <a href=\"https:\/\/www.energy.gov\/eere\/iedo\/process-heating\" target=\"_blank\" rel=\"noopener\">Recursos de calentamiento de procesos del Departamento de Energ\u00eda de EE. UU<\/a> proporciona un contexto m\u00e1s amplio de calentamiento de procesos, mientras que <a href=\"https:\/\/srdata.nist.gov\/CeramicDataPortal\/\" target=\"_blank\" rel=\"noopener\">Portal de datos de cer\u00e1mica del NIST<\/a> is a useful source for ceramic-material references. Keep calculations, drawings, and measured values under revision control so SiC heating element wiring diagram can be reviewed after process changes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Controles de seguridad y puesta en servicio<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Los equipos de calefacci\u00f3n el\u00e9ctrica deben ser dise\u00f1ados, instalados y puestos en servicio por personal calificado. Coordinar el proyecto con lo correspondiente <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/65072\" target=\"_blank\" rel=\"noopener\">Normas IEC para equipos de calefacci\u00f3n el\u00e9ctrica<\/a> y reglas del sitio. El <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.304\" target=\"_blank\" rel=\"noopener\">Requisitos de seguridad el\u00e9ctrica de OSHA<\/a> tambi\u00e9n ilustra por qu\u00e9 la protecci\u00f3n del conductor, la conexi\u00f3n a tierra, el aislamiento y la integridad de la conexi\u00f3n necesitan una verificaci\u00f3n formal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before first heat, verify identity, location, resistance where applicable, clearances, supports, terminal hardware, conductor routing, protection, transformer taps, and controller limits. Apply power in controlled stages and record voltage, current, output percentage, and temperature by zone. A commissioning baseline makes later SiC heating element wiring diagram troubleshooting faster and more credible.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Cinco preguntas para incluir en la discusi\u00f3n con proveedores<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>\u00bfQu\u00e9 dibujo y revisi\u00f3n definen la geometr\u00eda del elemento?<\/li><li>\u00bfQu\u00e9 valor el\u00e9ctrico est\u00e1 garantizado y en qu\u00e9 condici\u00f3n de referencia?<\/li><li>\u00bfQu\u00e9 informaci\u00f3n sobre la atm\u00f3sfera, la temperatura y el ciclo del horno se utiliz\u00f3?<\/li><li>\u00bfQu\u00e9 terminales, correas, cables, soportes o accesorios est\u00e1n incluidos?<\/li><li>\u00bfQu\u00e9 controles entrantes de inspecci\u00f3n y puesta en servicio se recomiendan?<\/li><\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">These questions keep SiC heating element wiring diagram focused on interfaces that affect the installed result. Send photographs and an existing element drawing when replacing equipment, but do not treat a photograph as a substitute for dimensions and electrical data.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Preguntas frecuentes<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">What information is essential for SiC heating element wiring diagram?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">At minimum, provide a dimensioned drawing, operating temperature, atmosphere, process cycle, electrical arrangement, resistance or power data, quantity, and connection details. Existing-furnace records improve the review. This makes SiC heating element wiring diagram easier to repeat consistently.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can SiC heating element wiring diagram be based only on maximum furnace temperature?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. Maximum temperature is only one input. Zone heat loss, atmosphere, loading, element geometry, controls, wiring, supports, and maintenance access can change the appropriate decision. This makes SiC heating element wiring diagram easier to repeat consistently.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u00bfPor qu\u00e9 deber\u00edan incluirse los datos medidos del horno?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Measured current, voltage, resistance, controller output, and temperature help distinguish design assumptions from actual operating behavior. They also reveal zone imbalance and aging trends. This makes SiC heating element wiring diagram easier to repeat consistently.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Who should approve SiC heating element wiring diagram?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The responsible furnace, electrical, process, and safety personnel should review their interfaces. A supplier can advise on the element, but the equipment owner and designer retain system-level responsibilities. This makes SiC heating element wiring diagram easier to repeat consistently.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u00bfC\u00f3mo debe registrarse la decisi\u00f3n final?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Keep the approved drawing, element schedule, calculation basis, quotation clarifications, inspection results, and commissioning baseline together. This record supports future replacement and troubleshooting. This makes SiC heating element wiring diagram easier to repeat consistently.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Cree una especificaci\u00f3n que pueda verificarse<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Good SiC heating element wiring diagram work converts furnace conditions into information that can be calculated, drawn, inspected, and measured. It reduces assumptions without pretending that every installation has the same answer. The most reliable next step is to collect the furnace drawing, electrical data, process cycle, atmosphere, and current operating record in one package.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si est\u00e1 preparando un nuevo proyecto o una solicitud de reemplazo, <a href=\"https:\/\/qixiangmaterial.com\/es\/contact-us\/\">p\u00f3ngase en contacto con el material Qixiang<\/a> con ese paquete. La discusi\u00f3n sobre ingenier\u00eda puede centrarse en la geometr\u00eda, la coincidencia el\u00e9ctrica, las interfaces de instalaci\u00f3n y las comprobaciones necesarias antes de la publicaci\u00f3n.<\/p>","protected":false},"excerpt":{"rendered":"<p>SiC heating element wiring diagram is not an isolated component decision. For electrical engineers, furnace builders, and commissioning teams, it connects the thermal duty of the furnace to the electrical system, mechanical layout, process atmosphere, and maintenance plan. The practical risk is that a drawing may look electrically complete while hiding unequal resistance, excessive branch [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":565,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[73,74,81,40],"class_list":["post-1128","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-furnace-engineering","tag-heating-element-specifications","tag-industrial-heating","tag-sic-heating-elements"],"_links":{"self":[{"href":"https:\/\/qixiangmaterial.com\/es\/wp-json\/wp\/v2\/posts\/1128","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qixiangmaterial.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qixiangmaterial.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qixiangmaterial.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qixiangmaterial.com\/es\/wp-json\/wp\/v2\/comments?post=1128"}],"version-history":[{"count":1,"href":"https:\/\/qixiangmaterial.com\/es\/wp-json\/wp\/v2\/posts\/1128\/revisions"}],"predecessor-version":[{"id":1160,"href":"https:\/\/qixiangmaterial.com\/es\/wp-json\/wp\/v2\/posts\/1128\/revisions\/1160"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qixiangmaterial.com\/es\/wp-json\/wp\/v2\/media\/565"}],"wp:attachment":[{"href":"https:\/\/qixiangmaterial.com\/es\/wp-json\/wp\/v2\/media?parent=1128"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qixiangmaterial.com\/es\/wp-json\/wp\/v2\/categories?post=1128"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qixiangmaterial.com\/es\/wp-json\/wp\/v2\/tags?post=1128"}],"curies":[{"name":"pp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}